Home
Product Catalog
Contact Us
News

Product Catalog 

Karl Fischer Moisture Titrator MKC-710M

  • Karl Fischer Moisture Titrator MKC-710M
  • Karl Fischer Moisture Titrator MKC-710M
  • Karl Fischer Moisture Titrator MKC-710M
  • Karl Fischer Moisture Titrator MKC-710M
Model No.︰MKC-710M
Brand Name︰KEM
Country of Origin︰Japan
Unit Price︰-
Minimum Order︰1 pc
Share on:

 Total 7 Related Items 
Prev12345Next

Product Description

Karl Fischer Moisture Titrator (Coulometric titration) [MKC-710M]

Large color TFT-LCD with a touch panel (8.4-inch) enables easy key entry
Up to 4 titrators , AT-710B potentiometric titrators or MKV-710B Volumetric or additional MKC-710B Coulometric Karl Fischer moisture titrators can be connected and simultaneous measurement is possible
Reduction of power consumption by 30% compared with the conventional product

Features

Up to 4 simultaneous measurements (Simultaneous titrations)
Can be connected to AT-710B potentiometric titrators or MKV-710B Volumetric Karl Fischer moisture titrators
The main control unit and a titrator are separately located by wireless (Bluetooth(R))
Large color TFT-LCD with a touch panel (8.4-inch)
Two different user levels and permissions
With a unique mechanism , the ceramic diaphragm of the optional titration cell unit can be replaced
Measurement results are converted to PDF and can be stored in a USB flash drive
By reviewing the conventional electrolytic control method , reduction of power consumption by 30%
When using ADP-611 , a patented scan mode automatically determines the optimal evaporation temperature. (Japanese Patent No. 4247093)
Manual solvent change unit is included

Specifications

Type

Karl Fischer Moisture Titrator

Model

MKC-710M

MKC-710S

Product configuration

MCU-710M+MKC-710+IDP-100+Automatic Solvent Change unit

MCU-710S+MKC-710+IDP-100+Automatic Solvent Change unit

Measuring method

Karl Fischer Coulometric titration

Measuring range

Water content / Bromine index : 10ug to 300mg (depends on reagent)

Measurement cell

2-Component or 1-Component

Precision

Relative standard deviation : less than 0.3% (n=10)
*Per KEM standard measurement conditions and standard liquids

Display resolution

0.1ug

Control method

Constant current pulse time control

Endpoint detection

Alternate current polarization method with a twin platinum electrode

EP sense method

Selective drift stability or limit measurement time

Required solvent

2-Component cell : Anolyte 100mL , Catholyte 5mL
1-Component cell : Anolyte 150mL

Method

120

Key operation

Touch panel

Displays

1) 8.4-inch color LCD 800 x 600 dots

2) English / Japanese / Mandarin Chinese / Korean / Russian / Spanish / German / French

3) Simultaneous 4-channel display (Can also display Automatic Potentiometric Titrator simultaneously)

3) 1-channel display

Calculation

Concentration of water content , statistics data processing (mean , SD and RSD) and automatic averaging of blank value and factor value

Data storage

500 samples

GLP conformance

Registration of operator / User group administration
Check performance with standard substance :
Reminder of scheduled check date / Record of check results
Reagent life control : Reminder of expiration/Reminder reagent replacement date
Management of conduction time : Display of operating time

External I/O

RS-232C port x4 :
for Dot matrix printer , Electronic balance , Data Capture Software (SOFT-CAP) , Evaporator , Multiple sample changer
USB ×1 :
for USB flash drive , Thermal printer , A4 printer , Keyboard , Barcode reader , Foot switch , USB HUB

LAN ×1 : for Personal computer (PC)

-

Extensibility

Measuring instrument :
Automatic Potentiometric Titrator (AT-710) , Karl Fischer Moisture Titrator (MKV-710/MKC-710)
Three of these instruments can be added

-

Evaporator ADP-611

Multiple sample changer : CHK-501

Ambient condition

1) Temperature

:

5 to 35°C

2) Humidity

:

85%RH or below (no condensation)

Power source

AC100 to 240V +/- 10% 50/60 Hz

Power consumption

Main unit

:

Approx. 30W

Printer

:

Approx. 7W

Dimensions

Touch-on panel controller

:

225(W) x 190(D) x 42(H) mm

Titration unit

:

141(W) x 292(D) x 244(H) mm

Stirrer

:

107(W) x 206(D) x 340(H) mm (not incl. Solvent Change unit)

Solvent Change Unit

:

240(W) x 140(D) x 405(H) mm (not incl. tubing)

Printer

:

106(W) x 180(D) x 88(H) mm

Weight

Touch-on panel controller

:

Approx.1.5kg

Titration unit

:

Approx.3.0kg

Stirrer

:

Approx.2.0kg

Solvent Change Unit

:

Approx.0.6kg

Printer

:

Approx.0.4kg

Conformity standard

CE marking EMC : EN61326-1 LVD : EN61010-1

 

KF Moisture Titrator ︰Karl Fischer Moisture Titrator MKC-710M
Product Image





Related Products
Karl Fischer Moisture Titrator MKV-710M
Karl Fischer Moisture Titrator MKV-710M
Volumetric Karl Fischer Titrator MKV-710S
Volumetric Karl Fischer Titrator MKV-710S
Coulometric Karl Fischer Titrator MKC-710S
Coulometric Karl Fischer Titrator MKC-710S
Volumetric KF Titrator MKV-710B
Volumetric KF Titrator MKV-710B




Home  |  Product Catalog  |  Contact Us  |  News  |  Sitemap  |  Mobile Version
  简体版     繁體版     English

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !